FUJI Computed Radiography (CR)

Fuji FCR XL-1   Fuji has pioneered the CR marketplace and has the most installs worldwide. Fuji incorporates renowned image processing technology to yield consistently high quality image resolutions. Fuji is the reader of choice for general purpose diagnostic & the standard of excellence in mammography readers.
Fuji FCR XG-1
Fuji FCR XG5000
Fuji FCR ClearView

 

.
FUJI FCR XL-1
PDF, 94 Plates Per Hour (14 x 14"), Single Bay Reader, 12 Bits Per Pixel Grayscale, HQ (10 pixel/mm) Spatial Resolution, Cassette Cycle Time: 60 Seconds, Cassette Sizes: 14 x 17", 14 x 14", 10 x 12", 8 x 10", Image Intelligence, Flash IP2 Console, Flex UI, Windows XP, Multi-objective Frequency Processing, Exposure Data Recognizer, Magnification and Zoom, Dynamic Range Control, Flexible Noise Control, HIPAA Audit Trail, Grid Pattern Removal, Black Border Masking, Reject Analysis, Out-of-range Dose Indicator, DICOM, Barcode Reader.
FUJI FCR XG-1
PDF, 62 Plates Per Hour (14 x 14"), Single Bay Reader,, 12 Bits Per Pixel Grayscale, HQ (10 pixel/mm) Spatial Resolution, Cassette Cycle Time: 64 Seconds, Cassette Sizes: 14 x 17", 14 x 14", 10 x 12", 8 x 10",  Image Intelligence, Flash IP2 Console, Flex UI, Windows XP, Multi-objective Frequency Processing, Magnification and Zoom, Dynamic Range and Noise Control, HIPAA Audit Trail, Grid Pattern Removal, Black Border Masking, Reject Analysis, Out-of-range Dose Indicator, DICOM, Barcode Reader.
FUJI FCR XG5000
PDF, 103 Plates Per Hour (14 x 17"), 4 Cassette Stacker, 12 Bits Per Pixel Grayscale, HQ (10 pixel/mm) Spatial Resolution, Cassette Cycle Time: 60 Seconds, Cassette Sizes: 14 x 17", 14 x 14", 10 x 12", 8 x 10",  Image Intelligence, Flash IP2 Console, Windows XP, Magnification and Zoom, Dynamic Range and Noise Control, HIPAA Audit Trail, Grid Pattern Removal, Black Border Masking, Reject Analysis, Out-of-range Dose Indicator, DICOM.
FUJI CLEARVIEW-1M
90 Plates Per Hour, Single Bay Reader, 10-20 Bits Per Pixel Grayscale, 50-Micron Resolution Mammography, 100-Micron Resolution General Radiology, 20-Second Scan Time, 15-Second Erase Time, Cassette Sizes: 24 x 30cm, 18 x 24cm, 14 x 17", 14 x 14", 10 x 12", 8 x 10",  Flash IP2m Remote Operators Console, Windows XP, Magnification and Zoom, Dynamic Range and Noise Control, HIPAA Audit Trail, Grid Pattern Removal, Black Border Masking, Reject Analysis, Out-of-range Dose Indicator, DICOM, Barcode Reader.
 

 

Print Film With      Fuji Laser Printers


Your Name
Your Email Address
Equipment
Comment
Facility
Address
City
State
Zip
Phone
Fax

Powered byEMF Email Form

 

 

 

 

 

   Register  |  Contact Us  |  Trade-In Cash  |  X-ray News  |  Pics  |  PDFs  |  Radiology Links Resellers  

 

Telephone ( 440 ) 953 - 4488  |  Terms & Conditions  |   Privacy Policy  |   Site Map   |    1999-2011 All Rights Reserved